Primary bath tub leak Liberty Township, OH
WHAT HAPPENED
- Cause of loss
- Water category
- Drying method
- Ceiling demo
- Finish preserved
- Monitoring
- Insurance support
- Primary bath (origin)
- W.I.C.
- Bath (secondary)
- Dining room (below)
- Living room (below)
- Basement rec room
- Total affected
A CLOSER LOOK AT THE DAMAGE
Work completed
Inspection and origin confirmed — primary bath soaking tub
Full inspection of the primary bathroom identified the soaking tub base as the leak source. The migration path was mapped from the bath floor assembly downward into the dining room and living room ceiling cavities below. Moisture readings taken at the ceiling surface in both rooms confirmed active saturation in the concealed assembly.
In-place drying assessment — injectidry selected
Before demolition began, a contents team inventoried and packed all belongings from the affected areas into labeled Content Restorology boxes. Toilets removed from both bathrooms were carefully staged in the bedrooms on protective plastic sheeting. All contents were documented for the insurance claim.
Injectidry system installation — ceiling probe ports
Small injection holes were drilled along the ceiling line at measured intervals across both the dining room and living room. Flexible drying hoses from the PDS-12 injectidry unit were threaded through the ports, directing pressurized airflow inside the ceiling cavity. Red-tip probes marked each injection point and allowed for easy repositioning as needed during monitoring.
Active drying — air movers and dehumidification
Multiple axial air movers were positioned to feed the injectidry system and maintain airflow through the wall cavities behind the wainscoting. An XPOWER LGR dehumidifier captured the moisture extracted from the assembly, venting dry air back into the space. The system ran continuously between monitoring visits.
Daily monitoring — readings logged across all zones
Commercial air movers and LGR dehumidifiers were deployed across the 1st and 2nd floors targeting the exposed joist cavity, kitchen subfloor, and bathroom framing. Thermal imaging confirmed no residual moisture pockets in the dining room or 2nd floor bedroom walls before equipment was removed.
Final documentation and adjuster scope submission
Complete before-and-after moisture documentation was submitted to the adjuster, including daily reading logs, equipment placement records, and the final dry verification readings. Scope covered: injectidry system deployment, daily monitoring, dehumidification, and source-side investigation at the primary bath — with the basement documented as unaffected. Probe holes were patched and the ceilings required no additional reconstruction.